Motor Protection Circuit Breaker J3VE

Shop Motor Protection Circuit Breaker J3VE at our factory. Durable and reliable, ensure your motor is protected. Order now for quick shipping!

Request a Quote
  • Motor Protection Circuit Breaker J3VE
  • Motor Protection Circuit Breaker J3VE
  • Motor Protection Circuit Breaker J3VE
  • Motor Protection Circuit Breaker J3VE
  • Motor Protection Circuit Breaker J3VE

PRODUCTS DETAILS

 Product number

Structural features

Main parameter

● This series of circuit breakers are mainly composed of mechanism, contact system, tripping device of arc extinguishing system, insulating base and shell. ● J3VE1 type circuit breakers are equipped with auxiliary contacts. J3VE3 and J3VE4 type circuit breakers are not equipped with auxiliary contacts, but they can be equipped with auxiliary contact accessories. ● There are two types of trips in circuit breakers: one is a bimetallic inverse time delay trip for overload protection; the other is an electromagnetic instantaneous trip for short-circuit protection. The circuit breaker also has a temperature compensation device, so the protection characteristics are not affected by the ambient temperature. ● J3VE1, J3VE3 and J3VE4 circuit breakers are operated by button, knob and handle respectively. ● The circuit breaker is installed in front of the board. J3VE1, J3VE3, type circuit breakers also have a standard mounting card, which can be directly installed on a standard rail with a width of 35mm (should comply with DINEN50022). ● The mechanism of J3VE3 and J3VE4 circuit breakers uses quick-on and quick-break structures, and their tripping devices have limited current characteristics, so the circuit breaker has a high short-circuit breaking capacity. ● The front of the circuit breaker has a pointer for adjusting the current of the tripping device, which can set the tripping current within the specified range. ● The circuit breaker can be attached with accessories such as undervoltage release, shunt release, indicator light, lock, and various protection types of enclosures. Please specify when ordering.

Outline and Mounting Dimension

Model 3VE1 3VE3 3VE4
Pole NO. 3 3 3
Rated Voltage(V) 660 660 660
Rated Current(A) 20 20 20
Rated breaking capacity of short circuit 220V 1.5 10 22
380V 1.5 10 22
660V 1 3 7.5
Mechanic life 4×104 4×104 2×104
Electric life 5000 5000 1500
Auxiliary Contact Parameters   DC AC    
Rated Voltage(V) 24, 60, 110, 220/240 220 380 It can be matched with the auxiliary contact only
Rated Current(A) 2.3, 0.7, 0.55, 0.3 1.8 1.5
Protective Features Motor Protection Su Current Multiple 1.05 1.2 6
Action Time No action <2h >4s
Distribution Protection Su Current Multiple 1.05 1.2  
Action Time No action <2h  
Model Rated Current(A) Release Current Setting area(A) Auxiliary contacts
3VE1 0.16 0.1-0.16 without
0.25 0.16-0.25
0.4 0.25-0.4
0.63 0.4-0.63
1 0.63-1 1NO+1NC
1.6 1-1.6
2.5 1.6-2.5
3.2 2-3.2
4 2.5-4 2NO
4.5 3.2-5
6.3 4-6.3
8 5-8
10 6.3-10 2NC
12.5 8-12.5
16 10-16
20 14-20
3VE3 1.6 1-1.6 Special
2.5 1.6-2.5
4 2.5-4
6.3 4-6.3
10 6.3-10
12.5 8-12.5
16 10-16
20 12.5-20
25 16-25
32 22-32
3VE4 10 6.3-10 Special
16 10-16
25 16-25
32 22-32
40 28-40
50 36-50
63 45-63

Hot Products

Timer With Digital Display

Timer With Digital Display

Big Power AC Contactor JLC1-F 115A~800A 380V

Big Power AC Contactor JLC1-F 115A~800A 380V

Analogue Type Timer With All kinds Voltage

Analogue Type Timer With All kinds Voltage

AC Contactor LC1-D0910  9A

AC Contactor LC1-D0910 9A

GV2-M motor protector with overcurrent protection

GV2-M motor protector with overcurrent protection

New Type AC Contactor 9A~40A 48V,220V

New Type AC Contactor 9A~40A 48V,220V

Motor Protector With Overload Protection JGV2

Motor Protector With Overload Protection JGV2

Analog Type Time Relay ST3P and ST2P

Analog Type Time Relay ST3P and ST2P

AC Contactor LC1-D4011 40A 220V

AC Contactor LC1-D4011 40A 220V

Standard Type Timer With 24V,220V

Standard Type Timer With 24V,220V

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours